Includes
everything shown above: the Iso-Shield-120, a 5 foot air intake
hose, power cord, and a wall coupling.

Accessories

Optional
NBC Upgrade kit
At any time in the future, you can upgrade your Iso-Shield-120
into a full Nuclear, Biological, and Chemical air filtration
system. This kit includes everything shown above: a nuclear
grade ASZM TEDA/NUKTK TEDA carbon adsorber, large side plates
and bolts. ASZM-TEDA carbon is the only carbon media
accepted by the US Military as effective for NBC protection.
Please
note that by installing this kit, you will reduce
the air output of your Safe Cell due to the added resistance
of the carbon adsorber - in short, it will reduce the maximum
size of the room that you use for a protected space. Keep
this in mind when choosing your isolation room if you plan
on upgrading your Iso-Shield-120 to a full NBC Safe Cell.


Optional
external 12 volt blower
This blower can be instantly installed on the top of the Iso-Shield-120
and will allow you to maintain an overpressure in your safe
room if the electrical power is interrupted. It features a
slip-fit connection for simple installation.
Please
note that you must have a charged 12 volt
automotive type battery to operate this blower.


Optional
emergency manual bellows
This hand-operated bellows will allow you to bring filtered
air into your protected space in the event of a long term
power outage. It instantly attaches to the top of the Iso-Shield-120.
Please
note that you will not be able to maintain an overpressure
with this bellows, but you will be able to replenish the oxygen
supply in your shelter and displace the carbon dioxide that
is created as the occupants exhale.

|
|
Protect
your family from avian influenza (bird flu)
The
CDC recommends
that people who have contracted avian influenza should be
placed in an infectious disease isolation room with 6 to 12
air changes per hour. We manufacture
a high-end negative pressure infectious disease air filter
called the Iso-Shield-800
for hospital use, and now, you can now have this same
level of protection at an affordable price in your home!
The
Iso-Shield 120 Safe Cell is a positive or negative pressure
air filtration system designed to isolate a room from airborne
pathogens. It's nuclear grade HEPA filter traps human or animal
droplet nulcei (airborne body fluids) from any communicable
disease, including H5N1 avian influenza (bird flu),
tuberculosis, SARS, and anthrax.
Once
set up in a room, you will have a protected space in your
home that is overpressured to deny access
to airborne pathogens that will enter through
the cracks around doors or windows. If you have a family member
that shows a bird flu symptom, you can turn
that room into a negative pressure hospital grade isolation
room in under a minute by switching the intake hose to the
outflow connector on the Safe Cell.

Features
The
centerpiece of every Safe Cell is the industrial grade, MIL-Spec
high efficiency particulate air (HEPA) filter. We have these
manufactured just for our application. They are light years
beyond what you will find in an average consumer product.
Please take a moment and read why we can make this
claim:
This
individual testing is what sets our HEPA filters apart from
all other consumer grade room air filters that claim to have
a "true HEPA filter." The testing is conducted using
a forward light scattering photometer. The HEPA is challenged
with 0.3 micrometer particles of dioctyl-phthalate (DOP).
By measuring the upstream and downstream concentration of
these particles, the HEPA filter cell efficiency can be calculated.
Also,
these HEPA filters carry an Underwriters Laboratories Classification
UL 586: This classification to insure that each HEPA filter
cell is individually tested at the factory. Additionally,
representative HEPA filter cells are tested by UL to ensure
that they provide their rated HEPA level filtration, after
being subjected to the following conditions of a high moisture
environment of (90% R.H.), a high temperature environment
of (371 deg/C), low temperature environment of (-3 deg/C).
UL also subjects the HEPA filter cell to a spot flame test
of 954 degrees Fahrenheit.
With
airborne pathogens like avian influenza, SARS, and tuberculosis,
why would you trust anything less?


click
on image to enlarge
The
simple controls of the ASR-120-IDF Safe Cell: On/Off switch,
fuse holder, and power cord socket.


Installation
and Operation Manual
Click here to view
this manual (PDF)


|